Initial Setup
VC3700 User’s Manual
Valco Cincinnati
48
7. Press the “ENTER” button. (The turn-off time displays in the “OFF=” window and the “OK DONE”
message displays.)
Note!
To set compensation times for channel 2, you press the “COMP CHAN2” button and enter the turn-
on and turn-off times as described above.
8. Press the “EXIT” button to return to the level-4 menu screen.
Unknown Compensation Value
When the compensation value is not known, follow these steps:
1. At the level-4 menu screen, set the channel’s on and off compensation to 0 (see previous page).
2. Adjust the cell-to-gun dimension for the channel until the leading edge of the pattern is correct at low
speed—that is, less than 75 feet (25m) per minute.
3. Increase machine speed to maximum.
4. Adjust the “ON” compensation until the leading edge of the pattern is correct. (Increasing the ON compen-
sation will move the leading edge of the pattern forward at high speeds.)
5. Adjust the “OFF” compensation until the trailing edge of the pattern is correct. (Increasing the “OFF”
compensation will move the trailing edge of the pattern forward at high speeds.)
Enable Glue QC
1. At the level-5 menu screen, press the “GLUE QC” button. The glue inspection setup screen displays.
2. Press the “MARKER” button. (The cell-marker edit screen displays.)
3. Using the numeric keypad, enter the distance from the first product scanner used for glue inspection to the
marker valve or kicker/diverter.
4. Press the “ENTER” button. (The “OK DONE” message displays.)
5. Press the “MARKER PATTERN” button. (The marker skip/marker mark select screen displays.)
6. Press the “MARKER SKIP” button. (The marker-pattern edit screen displays.)
7. Using the numeric keyboard, enter the distance required on each faulty product before marking
(a non-zero setting is required).
8. Press the “ENTER” button. (The “OK DONE” message displays.)
9. Press the “EXIT” button. (The marker skip/marker mark screen displays.)
10. Press the “MARKER MARK” button. (The marker-pattern edit screen displays.)
11. Using the numeric keyboard, enter the length of mark required on each faulty product (a non-zero setting is
required).
12. Press the “ENTER” button. (The “OK DONE” message displays.)
13. Press the “EXIT” button. (The marker-skip/marker-mark select screen displays.)
14. Press the “EXIT” button again (the cell-marker edit screen displays.)
15. Press the “EXIT” once more (the glue inspection setup screen displays).
Summary of Contents for VC3500
Page 1: ...VC3500 User s Manual Software Version 3 X Manual Number MCO35 Manual Release Date July 1999 ...
Page 19: ...Installation VC3500 User s Manual Valco Cincinnati 16 Figure 8 Internal Connections Diagram ...
Page 88: ...VC3700 User s Manual Software Version 3 X Manual Number MCO34 Manual Release Date July 1999 ...
Page 181: ...VC3500 VC3700 Troubleshooting Manual Manual Number MC048 Release Date May 1999 ...
Page 185: ...VC3500 VC3700 Troubleshooting Manual Valco Cincinnati Page 1 System Level Documents ...