VC3500/VC3700 Troubleshooting Manual
Valco Cincinnati
Page 24
Relay Board - 151xx404
(Reference Schematic 999xA151-220)
Service Access Points
Connectors
J1
Connection to drive Machine Interface relay from either J6 of the
Interface board (151xx366) or J1 of the Glue Inspection board
(151xx410).
J2
Connection to supply beacon and alarm signals from the Glue Inspection
board (151xx410).
J3
External connector used for interfacing the Machine Interface relay to
the parent machine stop circuit.
J4
External connector used for interfacing a Beacon/Alarm for Jam and
Glue Fault conditions.
Indicators
D1 (RLY)
When lit, this yellow LED indicates that the Machine Interface relay is
energized.
Replacement Fuses
Function Label
Type
Value
Valco
Number
Beacon current limit
F1
PC Mount
3A
085xx207
Schematic Description
Diode CR1 provides flyback voltage protection due to relay RL1. Varistors V1 and V2
provides suppression of contact arcing for relay RL1.
Summary of Contents for VC3500
Page 1: ...VC3500 User s Manual Software Version 3 X Manual Number MCO35 Manual Release Date July 1999 ...
Page 19: ...Installation VC3500 User s Manual Valco Cincinnati 16 Figure 8 Internal Connections Diagram ...
Page 88: ...VC3700 User s Manual Software Version 3 X Manual Number MCO34 Manual Release Date July 1999 ...
Page 181: ...VC3500 VC3700 Troubleshooting Manual Manual Number MC048 Release Date May 1999 ...
Page 185: ...VC3500 VC3700 Troubleshooting Manual Valco Cincinnati Page 1 System Level Documents ...