The Gallons used per heating device and the total gallons used are displayed under the Summary
menus. The gallons used calculations are very rough estimates and should not be used to determine
the amount of gas left in the tanks. Refer to page 147 for more detail on Gallons used.
Furnace, Heater & Brooder Settings - continued
If you have set the Heater to Curtains Interlock (refer to the Temperature Control Settings section) specify the
curtain (and ridge vent) groups here. When interlocking is enabled for heaters (and brooders and furnaces), and the
controller detects that the heater’s ON Temp has been reached, the heater will not turn on if the interlocked curtains
are open more than about one inch.
FURNACE GROUP #2 SETTING
Z1-S01
Interlock Curtain Grps: 1, 2, 3, 0, 0, 0
Input up to six curtain groups. Enter all zeros to interlock the heater with all groups.
FURNACE GROUP #2 SETTING
Z1-S01
Use During Heat Purge: Yes
Set Use During Heat Purge to YES to have this heater used to heat the building before a purge. (See Purge Settings for
more information)
The controller will perform a simple calculation to get a rough estimate of the number of gallons used by the heating
devices based on the size of the heater and whether the heater has a pilot light. Enter the BTU size (in thousands) of
the heating unit. If the heating unit has a pilot light then set the "Has Pilot Light" setting to YES.
FURNACE GROUP #2 SETTING
Z1-S01
BTUs 125000 Has Pilot Light: NO
Interlock Curtain Groups
Use During Heat Purge