90
® 2018 Valco Companies, Inc.
The “Air Sensor Shared” device uses all the settings from the air probe that are being shared, except for the Location
setting. The “Air Sensor Shared” Location setting has its own menu. This allows you to use an air probe installed in
a Growout location to be used while the controller is in Brood mode, for example. Press the Down arrow key, when
viewing the “Air Sensor Location Settings”, to view or change the “Shared Sensors” location.
Use the
ENTER, PLUS
or
MINUS
keys to scroll to the group or number that you desire to set-up or change.
SENSOR CALIBRATION AND SETTINGS Z1-S01
Air Sensor #03 Location: BROOD
SYSTEM
SETUP
If you change the Module/Channel number of a “Air Sensor” device, make sure you change them
for any associated “Air Sensor Shared” device or the shared device will not work and the module/
channel being used by the shared device will not be available.
If you delete the “Air Sensor” associated with this “Air Sensor Shared” device, make sure to delete
this shared device also. If the “Air Sensor” is deleted, but the “Air Sensor Shared” device isn’t, the
channel number of the “Air Sensor” will no longer be available and there will be alarms for the
“Shared Sensor”.
If you change the Temperature Offset of the “Air Sensor” which is pointed to by the “Shared Air
Sensor”, the “Shared Air Sensor” reading will also be adjusted by the offset.
Air Sensor Shared Device
The Air Sensor Shared device is a special air sensor.
When installing an “Air Sensor Shared” device, the group/device
number has to be unique, but the Module and Channel numbers need to match another “Air Sensor” device that is
already been set up.
This allows a zone to share an air probe that is installed in another zone, allowing you to control
devices based on the temperature in a different zone. If you try to install a shared air sensor to a station/channel that
does not have an air probe installed, you will recive an error message.
Use the
ENTER, PLUS
or
MINUS
keys to scroll
to the group or number that you desire to set-up or change.
SYSTEM & CONTROL DEVICE SET-UP Z1-S01
Press ENTER to ADD a Control Device. (This could be a CHANGE or DELETE menu)
Set-Up Error: Sharing Device Not Found!
Press CANCEL to continue
SYSTEM
SETUP
ENTER
ADD: Air Sensor Shared #1 Z1-S01
to Module 01 Channel 01.
+
ENTER
ENTER
*