APPENDIX 15 - System & Control Device Setup
APPENDIX 14 - Sensor Min/Max Settings
Security levels
Display
Edit
Time Setup
0
2
Date Set-up
0
2
Power Up Load Delay time
0
4
Press Enter to LIST Control Devices
0
0
Press Enter to ADD Control Devices
5
5
Press Enter to CHANGE Control Devices
5
5
Press Enter to DELETE Control Devices
5
5
Press Enter to ADD New Zone
5
5
Press Enter to DELETE New Zone
5
5
Disable Module with Address
9
9
Copy Zone/Mod: to Zone/Mod
9
9
Global Parameters
Display Language
0
0
Card Free Space
0
N/A
Number of Switches on front panel
0
0
Enter Options Password
0
Digital Alarm
Defaults
Min
Max
Steps By
Security levels
English Metric
English
Metric
English
Metric
English
Metric
Display
Edit
Trigger alarm on Active Input
No
“No” or “Yes”
N/A
0
4
Input is Active when
Closed
“Closed” or “Open”
N/A
0
4
Alarm Delay Time
0:01
0:00
59:59
N/A
0
4
Position Sensor (See Note 1)
Defaults
Min
Max
Steps By
Security levels
English Metric
English
Metric
English
Metric
English
Metric
Display
Edit
Attached To
Shows what Position Sensor is attached to - Allows all inlets installed
N/A
0
4
Enable Position Alarm
Yes
“No” or “Yes”
N/A
0
4
Percent OUT of Position to Alarm (Note 2)
10
0
80
1
0
4
Note 1: Shows “Sensor Not Calibrated” unless attached to an Inlet and calibrated correctly
Note 2: Only enabled if Enable Position Alarm is Yes
Whisker Switch
Defaults
Min
Max
Steps By
Security levels
English Metric
English
Metric
English
Metric
English
Metric
Display
Edit
Attached To
Shows what Whisker Switch is attached to - Allows all inlets installed
N/A
0
4
Validate Switch - Low
0
0
High Max - 1
1
0
4
High
0
Low value + 1
Note 1
1
0
4
Seconds delay alarm Out of Position
15
0
600
1
0
4
Note 1: The High Max value is the Full Open size of the airway device the Whisker Switch is attached to