208
® 2018 Valco Companies, Inc.
APPENDIX 17 - Cool Pads, Fogger & Mister Min/Max Settings
Cool Pad Low/High, In House Fogger
(Bird) and Mister (Hog) Settings
Defaults
Min
Max
Steps By
Security levels
English
Metric
English Metric English
Metric
English
Metric Display
Edit
Use Sensors
ALL (0,0,0,0)
0
# of Sensors
installed
1 (Only sensor #’s)
0
4
Time of Day to Enable
0:00
0:00
24:00
N/A
0
4
Disable
24:00
0:00
24:00
N/A
0
4
Humidity Disable (See Note 1)
100
0
100
1
0
4
ReEnable (See Note 1)
100
0
Humidity Disable
1
0
4
Temp+Humidity Disable (See Note 1)
220
30
220
1
0
4
ReEnable (See Note 1)
220
30
T + RH Disable
1
0
4
Full On Temp
110.0
43.3
-59.9
-51.0
160.0
71.1
0.1
0
4
Off Temp
79.0
26.1
-60.0
-51.1
On Temp - 0.1
0.1
0
4
Cycle # X On Temp
90.0 to
90.3
32.2 to
32.5
-60.0
-51.1
160.0
71.1
0.1
0
4
Cycle # X On Timer
0:00:00
0:00:00
9:00:00
N/A
0
4
Off Timer
0:10:00
0:00:00
9:00:00
N/A
0
4
Minimum On Temp
80.0
26.6
-60.0
-51.1
160.0
71.1
0.1
0
4
Min Temps
90.0,
90.1,
90.2,
90.3,
110.0
32.2, 32.3,
32.4, 32.5,
43.3
Calculated valves equal to Cycle #1 thru #4 On Temps and
Full On Temp
If Min On temp is Greater than Cycle #1 On Temp then
Values equal Cycle On Temps + Offset of Min On Temp to
Cycle #1 Temp
0
4
Note 1: Enabled only if Humidity Sensor Installed
Menus that appear for Cool Pad Low/High, In House Fogger (Bird) and Mister (Hog)
Enabled and Disabled (X means
Enabled)
No Hu
-
midity
Sensor
With
Humidity
Sensor
Use Sensors
X
X
Time of Day to Enable / Disable
X
X
Humidity Disable / ReEnable(See
Note 1)
X
Temp+Humidity Disable /
ReEnable(See Note 1)
X
Full On Temp / Off Temp
X
X
Cycle On Temp #X
X
X
Cycle On / Off Timer #1 to #4
X
X
Minimum On Temp
X
X
Min Temps
Note 1: Enabled only if Humidity Sensor Installed