Test Keyboard Keys
TEST KeyBoard Keys:
Press ENTER to start TEST!
This test allows the testing of the keys on the front of the controller. When you press ENTER, you are given 60
seconds for testing. During that time, press any of the hotkeys on the controller to verify the system is seeing the
key press.
ENTER
This test option allows you to test the output relays of the devices by simulating a temperature reading for the Air/
Temp sensors. To use it, Press ENTER and use the + and – keys to set the simulated temperature to the desired
degrees. When the controller goes to read a temperature probe, it will use this simulated temperature instead to
operate the system.
Temperature Control Simulation
Simulator Temperature: N/A
There are two ways to disable this feature:
1. Stop pressing keys on the controller for 10 minutes. The simulated temperature will reset to N/A and the system
will start using the real temperature probes again.
2. Set the simulated temperature on this screen to -55.0. The value will change to N/A and the system will start
using the real temperatures probes immediately.
Temperature Control Simulation
This test displays the digital inputs that are currently open for the selected station. Press the
PLUS
or
MINUS
keys to
select a station number.
TEST DIGITAL INPUT for STA 1
Press ENTER to display the digital inputs that are currently open.
+
ENTER
Press
ENTER
to display the digital inputs that are currently open.
INPUTS are OPEN for STA 01 -Press ENTER
1 2 4 6 (Note: 3 and 5 are missing to show they are CLOSED)
+
ENTER
Test Digital Input
Test Control Center Hardware - continued