Select the location of the air sensor. The location is important because the controller needs to know which sensors to
use for the various house control mode settings (found in the Temperature Control Settings menu).
SENSOR CALIBRATION & SETTING Z1-S01
Air Sensor #01 Location: BROOD
Note: You can set up devices in any zone at any time, but if you don't have an air sensor (or shared
air sensor) installed in the zone, the zone will be alarming.
If you are using an effective environmental temperature (EET) air sensor, input the calibration values printed on the
sensor’s tag. If no calibration values are available, use the default values that the controller displays.
Cal Values menu
will not show up for an air sensor if that air sensor’s “Use for Wind Speed” setting is set to NO.
SENSOR CALIBRATION & SETTING Z1-S01
Air #01 CAL Values: 550/ 90
If you are using an effective environmental temperature (EET) air sensor, and you want to factor
air speed into the temperature calculation, set this menu item to YES. If you are not using EET air
sensors, this menu item must be set to NO.
SENSOR CALIBRATION & SETTING Z1-S01
Air #01 Use for Wind Speed: YES
Use for Wind Speed
The Outside Air Sensor is always #13 and has its own Cable Length, Wire Gauge, and Offset settings. Press the Down
arrow key, when viewing the same Air Sensor Setting, to set the Outside Air Sensor settings.
SENSOR CALIBRATION & SETTING Z1-S01
Air Sensor #13 Cable Length: 50’
SENSOR CALIBRATION & SETTING Z1-S01
Air Sensor #13 Wire Gauge: 24AWG
ENTER
+
-
+
ENTER
+
Reminder: Use the PLUS or MINUS key to change, increase
or decrease a value or group within a menu.
or
Air Sensor Settings - continued
Location
Cal Values
Outside Air Sensor Settings
SENSOR CALIBRATION & SETTING Z1-S01
Air Sensor #13 Temperature Offset: +2.3
ENTER
+