APPENDIX 21 - Chimney Damper Min/Max Settings
Chimney Damper Settings
Defaults
Min
Max
Steps By
Security levels
English Metric English Metric English Metric
English Metric
Display
Edit
Cool Fans ON
0
4
#01 to #09 Fans ON (No Variable Fans)
0 - 8
0, 1, 2, 3, 4, 5, 6, 7, 8, 9
1
0
4
#01 to #09 Fans ON (Variable Fans)
0.0 to 8.0
0.0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5,
5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0
0.5
0
4
#01 to #09 Cool Fans Open
0.0
0
0.0
0
250.0
250
0.1
1
0
4
Fan Interlocks
All Ridge Fans
Interlock up to 9 installed Ridge Fans that have “Use for
Proportional Control” set to “Yes”
0
4
Cooling Open Sizes are:
Proportional
Proportional or Stepping
0
4
Full Opening Size
12
30
1
250
1
0
4
Full Open Travel Time
1:00
0:05
59:59
N/A
0
4
Full Close Travel Time
1:00
0:05
59:59
N/A
0
4
Perform Re-Sync at
0:00
0:00
24:00
N/A
0
4
Note: All Menus are enabled at all times
Sidewall, Tunnel, Ceiling Inlet Settings - Menus that appear for Inlets Based on “Operate As” -
Enabled and Disabled (X means Enabled)
Natural
Operate
Disabled
—-
Temp
Temp
Temp
—-
Static
Static
Static
Tunnel
Static
—-
Temp
Static
Temp
—-
Temp
Static
Static Pressure Pause Timer (See Note 3)
X
X
X
X
X
Operate as (See Note 1)
X
X
X
X
X
X
X
X
Cool Fans ON / Open
X
X
X
X
Natural Interlocks
X
X
X
X
Cooling Open Sizes are:
X
X
X
X
Tunnel Fans ON / Open
X
X
X
Tunnel Interlocks
X
X
X
Tunneling Open Sizes are:
X
X
X
Full Opening Size
X
X
X
X
X
X
X
X
X
Full Open Travel Time
X
X
X
X
X
X
X
X
X
Full Close Travel Time
X
X
X
X
X
X
X
X
X
Purge Opening Size (See Note 2)
Note 2
Note 2
Note 2 Note 2
Note 2
Note 2
Note 2
Note 2
Note 2
Pre-Open Timer (Not Tunnel Inlets)
X
X
X
X
X
X
X
Tunnel Entry Size/Exit Size:
X
X
X
X
X
X
X
X
Perform Re-Sync at
X
X
X
X
X
X
X
X
X
Close To xx when Curtain >= xx (Note 5)
X
X
X
X
Close OverrideTemperature (Note 6)
Note 5
Note 5 Note 5
Note 5
Looking at(x): (x = 1 to 4) (Note 6)
Note 5
Note 5 Note 5
Note 5
Note
: Static Modes will only show if Static Pressure Sensor Is Installed
Note 1: Enabled only if Static Pressure sensor installed or a fan installed and Tunnel is part of Operating Mode
Note 2: Enabled only if Purge On/Off times are greater than 0:00:00. If power building then Humidity Sensor needs to be installed and one fan has to run
during Purge and Humidity Purge Time and Delay has to be greater than 0
Note 3: Enabled only if Static Pressure sensor installed
Note 5: Enabled only for Temp Natual Modes.
Note 6: Enabled only when “Close To” Curtain size is greater than 0.