56
® 2018 Valco Companies, Inc.
Device motor run times (or position sensors if installed) are used to calculate the current opening size of curtains and
inlets. “
Sync
” or “
Exercise
” will appear at the end of the second line if the airway device is currently performing one
of those features.
Control Equipment Status Menus (Hot-Key) - continued
CONTROL EQUIPMENT STATUS Z1-S02
Side Curtain #1 Open: 17"
CONTROL EQUIPMENT STATUS Z1-S02
Sidewall Inlet #2 Open: 2"
CONTROL EQUIPMENT STATUS Z1-S02
Tunnel Inlet #2 Open: 0"
The ON/OFF status menu items for the various timers used to control lights and feeders is shown below.
CONTROL EQUIPMENT STATUS Z1-S02
Lights Group #1: OFF
CONTROL EQUIPMENT STATUS Z1-S02
Feeder Group #1: ON
The 24-hour feed sensor run times are in hrs:min format. The times are taken from the three most recent 24-hour
periods in the historical data (excluding the current hour). The most recent 24-hour total is displayed as the left-most
data.
The screen will display “Searching History Record for Data” for a few seconds while retrieving the information.
The 24Hr. Feed Sensor run times show how long a device was actually running during the previous
three 24-hour periods. The feed sensors are monitored at all times. The feed sensor group number
does not have to match a feeder’s group number to work. But if you want to activate an alarm when
-
ever a feeder is off longer than it should, a feed sensor needs to be assigned the same group number
as the feeder.
CONTROL EQUIPMENT STATUS Z1-S02
24Hr. Feed Sensor #1 Run: 12:30, 9:00, 11:22
Press the PLUS or MINUS keys to change the feed sensor group number.
Run time is totaled for each feed sensor (days, hours, minutes and seconds). If more than one feed sensor is
installed, press the PLUS and MINUS keys to scroll through the feed sensor group numbers. Press ENTER while
viewing the total to reset it to zero. Press the LEFT arrow key to confirm the reset action.
CONTROL EQUIPMENT STATUS Z1-S02
Feed Sensor #9 Total Run Time: 10 10:46:50
All Current Equipment Status screens require the pressing of the PLUS or MINUS keys
to change the group number, if more than one of the device type is installed. Ex
-
ample: two sidewall fans require a press of the Plus key to see sidewall fan #2, when
viewing sidewall #1.
Curtains, Ridge Vents and Inlets
Equipment Timers
CONTROL EQUIPMENT STATUS Z1-S02
VariLights #1 ON at 57%