63
® 2018 Valco Companies, Inc.
The controller makes many decisions based on temperature. The Temperature Control Settings menu allows you to
input preferences for temperature-related decisions. Be sure to complete these menu items before setting up
specific devices (fans, heaters, etc.). The information entered here, especially temperature setpoint, impacts most
installed devices.
You should determine what your temperature setpoint will be before inputting or editing
individual temperature settings for control devices.
This is your target building temperature. The controller calculates the on and off temperatures for devices based on
the current temperature setpoint.
Changing the Setpoint will cause the following values to change:
TEMPERATURE CONTROL SETTING Z1-S02
Temp Setpoint: 71.0 (Ramping ON)
Actual or effective temperature, or a blend of the two, can be used to control the building environment. This is called
the working temperature. The controller uses the
working
temperature to determine when to turn devices on and
off. The Temp Control can also be set to OFF.
See NOTE below on what happens when “Temp Control” is set to
OFF.
Effective
takes into account the effect that air speed has on how comfortable the animal feels.
Actual
uses the actual
air temperature only.
When setting the temperature control, use the PLUS or MINUS keys to move the asterisk (*) right
or left, or to select the OFF mode (the asterisk is replaced by the word OFF). Moving the asterisk
to the right increases the amount of effective temperature used to calculate the working tem
-
perature. If you are not using an air speed/temp sensor such as Air Sensor Model 935, move the
asterisk fully toward Actual.
TEMPERATURE CONTROL SETTING Z1-S02
Temp Control: Actual *---------- Eff.
The OFF mode causes the controller to turn off all temperature controlled output devices
and disable the normal alarms. Changing Temp Control to OFF also sets the Beginning Head
Count (Current Animal Information menu) to zero in addition; turns off all output channels,
so no fans, inlets, etc. will work. The controller still continues to read inputs and store
history. This mode is designed to conserve energy costs when the building is empty.
CONTROL
SETTINGS
CONTROL
SETTINGS
Temperature Control Settings Menu
Temperature Setpoint
Controlling Building Temperature: Actual or Effective
• Temperature Control Settings
• Purge and Minimum Vent Settings
• Sound Alarm When settings
• Fixed Fans; Stir, Sidewall, Tunnel, Ridge, Pit
• Variable Fans; Stir, Side, Tunnel, Ridge, Pit
• Heater Settings; Brooder, Furnace, Heater
• Mister Settings; In House Fogger, Cool Pad Low/High, Mister
• Curtain Inlets
• Ridge Vents
Set the Temp Setpoint manually or have the temperature ramping feature automatically adjust it every day at
midnight. If the animal age is within the age settings in the temperature setpoint ramp table (explained later),
ramping is ON. When ramping is ON, the setpoint may NOT be manually adjusted. Temperature settings for control
devices (fans, heaters, etc.) automatically track along with temperature setpoint changes.