137
® 2018 Valco Companies, Inc.
You can enter as many time slots per age as are available. There is no incremental ramping of the times between age
settings. The program uses the time slots with the oldest Age setting that is less than or equal to the current animal
age and uses those Age slots to control the lights. Example: In the images above, the controller will use time slot #1
from Age 5 to Age 9. At Age 10, the controller will use time slot #2.
You can enter the time slots in any order you want. Shortly after you enter the information, the controller will sort the
time slots from the earliest Age to the oldest Age.
Feeder Settings
30 time slots are provided to allow turning the Feeders on and off based on the age of the animals. To set the timer
slots, enter the age of the animals the time slot should be used for and then enter the times to turn on and off the
feeders. The on and off times use a 24-hour clock format. To set a feeder group for continuous on, set the ON time for
to 00:00 and the OFF time to 24:00. Press the UP and DOWN arrow keys to change the Setting number.
FEEDER GROUP #1 SETTING Z1-S01
Setting #
Age= ON=
OFF=
CONTROL
SETTINGS
DEVICE / EQUIPMENT SETTINGS
Z1-S01
PRESS ENTER TO VIEW SETTINGS
FEEDER GROUP #1 SETTING Z1-S01
Setting #
Age= ON=
OFF=
FEEDER GROUP #1 SETTING Z1-S01
Setting #
Age= ON=
OFF=
+
ENTER
+
+
Age, On Time and Off Time
Instant Run
The “Run For” feature provided the ability to immediately turn on the Feed system for the set amount of time. When
the time is set, the feed system will turn on, the timer will count down and when it reaches 0:00:00, the feed system
will return to normal operations based on the Feeder’s Age/On/Off schedules. This allows the ability to turn on the
feed system temporarily without having to worry about turning them off, such as when the feed in a bin hangs up, or
the bin runs out and you have to start a new one.
The amount of time the feed system runs, when this feature is enabled, is recorded in the Actual and
Calculated hourly history runtimes for the Feeder in the same way the runtimes are recorded for a
normal feed schedule.
CONTROL
SETTINGS
DEVICE / EQUIPMENT SETTINGS
Z1-S01
PRESS ENTER TO VIEW SETTINGS
FEEDER GROUP #1 SETTING Z1-S01
Run For 0:54:03
+
ENTER