Controller based fault conditions include the Controller
status and LON communications such as the
heartbeat being sent around the loop and the field
device loss of communications. Controller based fault
conditions are listed in Table 2-1.
Field device based fault conditions are transmitted to
the Controller, where they are then annunciated. Refer
to Table 2-2 for a listing of field device faults. Each
field device transmits its status to the Controller
on a regular basis.
When an alarm condition occurs, the Controller
displays the alarm condition on the text display,
activates the appropriate Alarm LED(s), and activates
the alarm signal using the Controller’s internal
annunciator.
Each field device must communicate alarm and fault
conditions to the Controller. The timing for transmitting
alarms and faults to the Controller is displayed in
Table 2-3.
Controller Faults
trouble
Lon Fault
trouble
shown on text Display
LED
LED
Relay
Controller Fault
X
X
Device Offline
X
X
Extra LON Device
X
X
Invalid Config
X
X
Lon Fault
X
X
X
LON Ground Fault
X
X
Power Fail 1
X
X
Power Fail 2
X
X
RTC Fault
X
X
Redundancy Fault*
X
X
Field Device Faults
trouble
trouble
shown on text Display
LED
Relay
290 Volt Fault
X
X
AC Failed
X
X
Battery Fault
X
X
Beam Block
X
X
Calibration Fault
X
X
Channel Open
X
X
Channel Short
X
X
Dirty Optics
X
X
Ground Fault Negative
X
X
Ground Fault Positive
X
X
IR Auto Oi Fault
X
X
IR Fault
X
X
IR Manual Oi Fault
X
X
Low Aux Power Fault
X
X
Missing IR Sensor Fault
X
X
Missing UV Sensor Fault
X
X
Power Supply Fault
X
X
Sensor Fault
X
X
Supply Voltage Fault
X
X
Tx Lamp Fault
X
X
UV Auto Oi Fault
X
X
UV Fault
X
X
UV Manual Oi Fault
X
X
Table 2-1—Controller Based Faults
Table 2-2—Field Device Based Faults
Table 2-3—Eagle Quantum Premier Status Update Rates
number of Devices
output Devices
old input Devices
newer input Devices
ARM
IDC
DCU*
SAM
UV Detector
DCIO*
UVIR Detector
X3301*
X3302*
PIRECL*
OPECL*
X5200*
X2200*
X9800*
AIM*
IPM*
PSM
1 to 100
1 Second
1 Second
1 Second
101 to 200
2 Seconds
2 Seconds
2 Seconds
201 to 246
5 Seconds
2 Seconds
3 Seconds
*Alarms are transmitted immediately. For Eclipse, the Status Update Rate is 1 second for all network sizes.
*Only for controller pair configured for redundancy.
Summary of Contents for DET-TRONICS 95-8533
Page 128: ...7 1 95 8533 A 4 Figure A 1 System Drawing 007545 001 ...
Page 129: ...95 8533 A 5 7 1 Figure A 2 System Drawing 007545 001 ...
Page 131: ...95 8533 7 1 B 2 Figure B 1 Drawing 007546 001 ...
Page 132: ...95 8533 7 1 B 3 Figure B 2 Drawing 007546 001 ...
Page 134: ...95 8533 7 1 C 2 Figure C 1 Drawing 007547 001 ...
Page 141: ...95 8533 7 1 D 7 Figure D1 System Drawing 007545 001 ...
Page 143: ...APPENDIX E E 1 95 8533 7 1 ...