Page | 23
•
If you have PRO series, click on the battery icon on the toolbar so that ISY goes back
to normal mode
5.2.1.7Restore Modem (PLM)
This operation is most useful when you need to replace a defective PLM and the ISY is
rebooted with a new PLM. When the communication links were established via the Link
Management Menu, the PLM and INSTEON devices adds each device addresses it is linked
to, in its own link table.
The ISY also reads and stores the PLM’s address at boot up. The ISY stores all the
configurations settings of the lighting network. If you are replacing a PLM the ISY will have
the old PLM address link stored in it.
Warning:
Never replace your PLM while the ISY is running because it will assume it is still
connected with the old PLM. The ISY will appear to work, but it will be writing the address of
the old PLM into the device links, thus you will not see devices updates etc.
If this menu option is selected, the ISY goes through all INSTEON devices looking for old
and new PLM address links. If an old PLM address link is found, it replaces them with the
address of the new PLM and adds the corresponding device link to the new PLM.
To replace a PLM:
•
Unplug ISY from the power outlet
•
Unplug the PLM from ISY and power outlet
•
Connect ISY’s port A to the new PLM
•
Plug the new PLM into a power outlet
•
Plug ISY into a power outlet
•
Go to Admin Console and wait for system initialization to complete
o
If you have
PRO Series
, click on the Battery icon at the top. This will prevent
ISY from trying to update programming on your RF devices which are
probably in sleep mode
•
Click on the
Restore Modem (PLM)
menu option
o
In case ISY cannot communicate (or decides not to if an RF device/PRO
Series) during the process, you will have a series of nodes with green 1011
icons in the device tree. For each one of those nodes:
▪
If an RF device, ensure that the device is in Programming mode
▪
Right mouse click | Write pending updates ...
If the above procedure fails on many of your devices, it's highly recommended that
you follow the instructions for
Restore Devices
.
5.2.1.8Delete Modem (PLM)
Before selecting this function, create a backup ISY file.
Summary of Contents for ISY-994i Series
Page 1: ...The ISY 994i Home Automation Cookbook ...
Page 35: ...Page 12 Figure 6 UDAjax Main Screen ...
Page 36: ...Page 13 Figure 7 UDAjax Devices Scenes Screen ...
Page 68: ...Page 45 Figure 44 NodeServer Configuration popup 5 2 5 Tools Menu Figure 45 Tools Menu ...
Page 102: ...Page 79 6 6 3 2Activate My OpenADR Portlet Figure 77 OpenADR My OpenADR Menu Option ...
Page 103: ...Page 80 6 6 3 3Configure OpenADR Settings Figure 78 OpenADR Settings Menu Option ...
Page 104: ...Page 81 Figure 79 OpenADR Settings Display ...
Page 108: ...Page 85 6 6 3 7Issue an Event Figure 84 OpenADR Issue and Event ...
Page 110: ...Page 87 Figure 86 OpenADR Event Viewer ...
Page 116: ...Page 93 Figure 92 ElkRP2 Account Details M1XEP Setup Button In the M1XEP Setup Window ...
Page 267: ...Page 244 Figure 189 State Variables ...
Page 268: ...Page 245 Figure 190 Programs and Folders ...
Page 292: ...Page 269 Figure 192 Irrigation Folders Figure 193 Irrigation Devices ...
Page 376: ...Page 353 Figure 209 Save Topology File ...
Page 433: ...Page 410 Figure 242 X 10 recognized as Living Room East Device ...
Page 540: ...Page 517 Figure 357 In Car Detection 12 Figure 358 In Car Detection 13 ...
Page 602: ...Page 579 Figure 382 SecureCRT SSH Raspberry PI Session ...
Page 685: ......