Page | 115
indicating LEDs or a KeypadLinc's button LED, will be updated when the scene is controlled
from any other controller in the scene. In this sense, an ISY scene is a multi-directional
group. If a scene were created manually without ISY, all of the required unidirectional
INSTEON group links and cross-links would need to be manually created.
It should be noted that all links created by ISY are standard INSTEON links and are stored
in the INSTEON devices. Therefore, after the required scenes are created, the ISY/PLM
could be removed from the network, and the scenes would continue to function as
programmed.
7.6.4
Working with Scenes
Selecting a scene in the Main tab's tree view will display in the top portion of the right pane,
a list of all devices which are responders in that scene together with their current status,
similar to the list of all managed device displayed when My Lighting is selected. The bottom
portion of the right pane will display the ISY scene settings on-level and ramp-rate sliders
for each of the scene's responder devices. These are the settings which will be used when
the scene is controlled by ISY, either in response to user actions in the GUI, or in response
to ISY programs or schedules.
When the scene is expanded in the tree view, it opens a list of all devices in the scene, with
controllers displayed in red typeface, and responders in blue typeface. Selecting a
controller within a scene displays in the right pane a list of the scene's responder devices
with status on top, and a list of their on-level and ramp-rate settings on the bottom, similar
to that displayed when the scene is selected. But in this case, the settings displayed are the
controller-specific scene settings which will take effect when that particular controller is
used to control the scene. When these settings are changed, the changes take effect
immediately.
Selecting a responder device within a scene displays in the right pane the device's status
and local settings, and is the same display as shown when the device is selected in My
Lighting. Changing these settings in either location will have the identical effect.
7.6.5
Adding a New Scene
To add a new scene, open the Link Management menu and choose New Scene. A New Scene
window will be displayed, allowing the new scene to be given a name.
7.6.6
Removing a Scene
In the tree view of the Main tab, right-click on the scene and from the context menu choose
Remove Scene. A Confirm window is displayed, and if OK is chosen the scene is removed.
Summary of Contents for ISY-994i Series
Page 1: ...The ISY 994i Home Automation Cookbook ...
Page 35: ...Page 12 Figure 6 UDAjax Main Screen ...
Page 36: ...Page 13 Figure 7 UDAjax Devices Scenes Screen ...
Page 68: ...Page 45 Figure 44 NodeServer Configuration popup 5 2 5 Tools Menu Figure 45 Tools Menu ...
Page 102: ...Page 79 6 6 3 2Activate My OpenADR Portlet Figure 77 OpenADR My OpenADR Menu Option ...
Page 103: ...Page 80 6 6 3 3Configure OpenADR Settings Figure 78 OpenADR Settings Menu Option ...
Page 104: ...Page 81 Figure 79 OpenADR Settings Display ...
Page 108: ...Page 85 6 6 3 7Issue an Event Figure 84 OpenADR Issue and Event ...
Page 110: ...Page 87 Figure 86 OpenADR Event Viewer ...
Page 116: ...Page 93 Figure 92 ElkRP2 Account Details M1XEP Setup Button In the M1XEP Setup Window ...
Page 267: ...Page 244 Figure 189 State Variables ...
Page 268: ...Page 245 Figure 190 Programs and Folders ...
Page 292: ...Page 269 Figure 192 Irrigation Folders Figure 193 Irrigation Devices ...
Page 376: ...Page 353 Figure 209 Save Topology File ...
Page 433: ...Page 410 Figure 242 X 10 recognized as Living Room East Device ...
Page 540: ...Page 517 Figure 357 In Car Detection 12 Figure 358 In Car Detection 13 ...
Page 602: ...Page 579 Figure 382 SecureCRT SSH Raspberry PI Session ...
Page 685: ......