50
6
EXPLANATION OF COMPARISON FUNCTIONS
50
EX
PLAN
ATION
OF C
O
MPAR
IS
ON FUN
C
TION
S
Chapter
6
6-1.
HI/LO limit comparison
Set the HI/LO limit of torque and rotation speed. (Hold synchronized)
≪
Setting value
≫
- Torque
HI limit/LO limit:
-99999 to 99999
- Rotation speed
HI limit/LO limit:
0 to 99999 (During low speed rotation mode: 0 to 9999.9)
<
HI/OK/LO output conditions
>
- HI
Indicated value
>
HI limit
- LO
Indicated value
<
LO limit
- OK
LO limit
≦
Indicated value
≦
HI limit
Overload of the torque and rotation speed is monitored. (Hold not synchronized)
When they exceed the alarm HI limit or fall below the alarm LO limit, the external output "ALM"
turns ON.
≪
Setting value
≫
- Torque
Alarm HI limit:
-99999 to 99999 (invalid at 99999 (initial value))
Alarm LO limit:
-99999 to 99999 (invalid at -99999 (initial value))
- Rotation speed
Alarm HI limit:
0 to 99999 (invalid at 99999 (initial value))
(During low speed rotation mode: 0 to 9999.9)
Alarm LO limit:
0 to 99999 (invalid at 0 (initial value))
(During low speed rotation mode: 0 to 9999.9)
- For initial value, since both the alarm HI and LO limits are invalid as default settings, set them
again for use.
- Since the alarm HI limit and LO limit are independent, simple use of either one of them is also
possible.
■
HI/LO limit setting method
See "
≪
HI/LO limit setting mode function
≫
" on page 20.
■
Alarm HI and LO limits setting method
See "
≪
HI/LO limit setting mode function
≫
" on page 20.
6
EXPLANATION OF
COMPARISON FUNCTIONS
With ±LOAD, OFL1, or OFL2 on torque, torque HI, LO is forcedly turned on.
With OFL2 on rotation speed, rotation speed HI, LO is forcedly turned on.
Point
Summary of Contents for TM380
Page 1: ...TM380 20MAY2021REV 1 02 TORQUE MONITOR OPERATION MANUAL ...
Page 11: ...Contents X Contents X M E M O ...
Page 147: ......