12-9.
Conformity with EC directives
The TM380 Torque Monitor is a CE-marked EC-Directive-conforming product (by the Council of
the European Union).
- EMC Directives;
EN61326-1
EN55011
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
■
Attachment of the ferrite core
Wind the power cable around the included ferrite core (SEIWA ELECTRIC MFG.: E04SR211132).
Attach the ferrite core as close to the TM380 body as possible.
Fix it with cable tie(s) as necessary.
CAUTION
●
Since the TM380 is defined as open type (built-in equipment), be sure to use it as
installed and fixed to a panel, etc.
●
Use shielded cables (for encoder, USB, external input/output, UTM, and option(s)).
EMC Directive EN61000-4-5 (Lightning Surge Immunity) is met by the TM380
body in combination with a lightning surge protector.
Point
power cable
Wind the cable around
the ferrite core (one turn)
TM380 body
Ferrite core