93
10
OPTION INTERFACE
93
OP
TION IN
TERFA
C
E
Chapter
10
10-3.
D/A converter voltage output (3ch)
This converter is used for obtaining analog outputs synchronized with torque, rotation speed and
angle.
The analog output ranges are -10 to +10V output.
By using the D/A zero setting and D/A full scale setting functions, analog output can be obtained
between zero (0V) and full scale (+10V) with respect to the predetermined digital value.
The output circuit and the main unit circuit are isolated.
The resolution is 1/10000 with respect to the ranges of -10 to +10V, and the conversion speed is
8000 times per second.
The maximum voltage output range are about ±11V.
■
Connector pin assignment
Compatible plug
734-106/037-000
Operating tool
734-230
1
Torque
+
VOUT
-
GND
2
Rotation speed
+
VOUT
-
GND
3
Angle
+
VOUT
-
GND
Voltage output terminals:
terminals to extract voltage signals.
-10 to +10V can be obtained.
1: Torque
2: Rotation speed
3: Angle