5
1
OUTLINE
5
OUTLINE
Chapter
1
■
Rear panel
■
UTM
Ⅲ
(UTM
Ⅱ
)
UTM
Ⅲ
/UTM
Ⅱ
connection connector
Connect a UTM
Ⅲ
/UTM
Ⅱ
with a dedicated cable.
* For connection, see "
■
UTM
Ⅲ
/UTM
Ⅱ
connection" on page 11.
Rotary encoder connection connector
Connect the optional rotary encoder for UTM
Ⅲ
/ UTM
Ⅱ
with a dedicated cable.
* For connection, see "
■
UTM
Ⅲ
/UTM
Ⅱ
connection" on page 11.
Voltage output terminal
The approximate input voltage from UTM
Ⅲ
(UTM
Ⅱ
) can be confirmed.
(approx. 1V per sensor input voltage of 1V, with load resistance of 2k
Ω
or more)
* For connection, see "
■
Voltage output" on page 13.
Signal input/output connector
Connect external input/output signals or SI/F (serial interface).
* For connection, see "
■
External I/O connection" on page 14.
DC power input terminal block
Connect the DC power cord. The power supply voltage is 24V DC (±15%).
* For connection, see "
■
DC power input terminal connection" on page 10.
Frame ground
Please ground the frame ground terminal to prevent failures due to static electricity.
(The frame and the frame ground terminal are conducted.)
It may be better to remove depending on the environment of the installation location.
Signal input/output
DC power input
Voltage output
Options slot
UTM
Ⅲ
/UTM
Ⅱ
terminal block
connector
connection
connector
terminal
Frame ground
Rotary encoder
connection
connector
Summary of Contents for TM380