32
4
CALIBRATION PROCEDURE
32
CALIBRATION P
R
OCEDURE
Chapter
4
②
Min. scale division (rotation speed) setting
Set the minimum unit (scale interval, scale division) of the rotation speed.
≪
Setting value
≫
0: 1 1: 2 2: 5 3: 10
During low speed rotation mode
0: 0.1 1: 0.2 2: 0.5 3: 1.0
◇
How to set the pulse rate and min. scale division of rotation speed
1.
Select setting mode 4.
Press
→
three
times.
2.
Set the "Pulse rate" and "Min. scale division" of
rotation speed.
Press
seven times.
⇒
"Calibration function
select 2" is displayed.
Press
, and the highest digit blinks.
①
Select pulse rate (rotation speed).
Input the pulse rate with
, and move to
the lower digit with
. (Initial value: 1)
②
Select min. scale division (rotation speed).
Input the min. scale division with
,
and validate it with
.
(Initial value: 0)
3.
Press
twice to go back to the indicated
value display.
■
Low speed rotation mode
When meet requirements below, it changes to low speed rotation mode and is able to indicate the
rotation speed down to one decimal place.
- Pulse rate (rotation speed) (F4-7)
4: Encoder pulse
- Encoder pulse (F7-2)
Over 600 pulses
Speed
rpm
Angle
rad deg
FNC
Torque
Speed
rpm
Nm
1
0
0
0
0
《
Setting value
》
H I
LO
HOLD
Undefined
Undefined
Undefined
Min. scale division
0: 1
1: 2
2: 5
3: 10
Pulse rate (rotation speed)
0: 1 pulse
1: 4 pulses
2: 60 pulses
(Fixed for UTF option)
Angle
rad deg
3: 90 pulses
4: Encoder pulse
(rotation speed)
RECALL
RECALL
RECALL
ESC
Summary of Contents for TM380