EXPLANATION OF HOLD FUNCTIONS
64
EXPLANATION OF HOLD FUNCTIONS
Chapter
7
■
Level + time
By this method, the hold detection section is specified as a timer. Hold is detected during the
predetermined time (hold section time) from the point in time when the torque crosses the hold start
level.
The hold value is maintained until the hold reset signal is turned on.
The hold is released by turning on the T/H signal as a reset signal.
There are tracking sections, detection sections, and hold deciding sections.
(Example) Level + Time specified section peak hold
t1: A delay time between the instant
when the indicated value exceeds
the hold start level and the instant
when the value to be held is
detected
Approximately 0.5ms (MAX.)
t2: A delay time between the instant
when the detection time is ended
and the instant when the value to be
held is determined
Approximately 1.0ms (MAX.)
t3: A minimum reset signal width
required for releasing the hold
Approximately 1.0ms (MIN.)
■
Hold start level
Set the start level in the case where the Section setting is Level + Time for Peak, Valley, P-P,
Average, or Angle peak hold.
《
Setting value
》
-99999 to 99999
◇
Hold start level setting method
1.
Select setting mode 1.
Press
once.
2.
Set "Hold start level."
Press
nine times
⇒
"Hold start level" is
displayed.
Press
, and the highest digit blinks.
Move to the lower digits with
. (Initial value: 100)
Input the setting value with
.
Press
to validate it.
3.
Press
twice to go back to the indicated value display.
Indicated
t3
Sensor input value
Detection
t
+
HI-LO Limit
Judging Output
H/E
Hold section
t2
t1
Fixed
T/H
Hold Start
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Blink
OFF
ON
OFF
Detection
HOLD
Status Display
Level
value
Time
Speed
rpm
Angle
rad deg
FNC
Torque
Speed
rpm
Nm
H I
LO
HOLD
Angle
rad deg
RECALL
RECALL
ESC