103
10
OPTION INTERFACE
103
OP
TION IN
TERFA
C
E
Chapter
10
■
Angle analog output select
Can specify zero/full scale for angle analog output.
《
Setting value
》
0: Number of rotations
Select number of rotations at encoder as standard.
1: Pulse rate
Select pulse rate at encoder as standard.
Can set in small scale.
Example) For 360° (1 rotation), set full scale value when outputting full scale at 10V
1
(0: When number of rotations is selected)
3600
(1: When pulse rate is selected, and encoder pulses are 3600
)
◇
Angle analog output select setting method
1.
Select setting mode 5.
Press
→
four times.
2.
Set "Angle analog output select."
Press
four times.
⇒
"Angle analog output select"
is displayed.
Press
, and present set value blinks.
Input the setting value with
.
(Initial value: 0)
Validate it with
.
3.
Press
twice to go back to the indicated value display.
Speed
rpm
Angle
rad deg
FNC
Torque
Speed
rpm
Nm
H I
LO
HOLD
Angle
rad deg
RECALL
RECALL
ESC