9-1.
Record timing
Each value (torque, rotation speed, and angle) is recorded according to a print command. Up to 30
pieces of the most recent data can be stored. If 30 pieces are exceeded, the oldest data in
chronological order will be overwritten. Select hold value (when hold is reset) or stable value (at
stable-time out of near zero) of the SI/F print setting. (For details, see "
■
SI/F print" on page 69.)
Even without using hold, data can be immediately recorded by setting SI/F print to hold value and
by pressing
or turning T/H ON.
In addition, when using hold with SI/F print at hold value, the value is recorded at the time of
release.
9-2.
History
Recorded data can be checked on the indicated value display screen in history mode.
1.
Enter the history mode with
from the indicated
value display.
2.
The most recent data are
displayed.
Rotation speed and data No.
are displayed alternately.
No. 00 corresponds to the
most recent data.
Data can be checked with
and
.
No. 29 (30 pieces old)
corresponds to the oldest
data.
9
RECORD FUNCTION
HOLD
Record
t
T/H (I)
HOLD
or
Torque
Speed
rpm
Nm
Torque
Speed
rpm
Nm
Torque
Speed
rpm
Nm
Torque
Speed
rpm
Nm
Torque
Speed
rpm
Nm
Torque
Speed
rpm
Nm
Torque
Speed
rpm
Nm
H I
LO
HOLD
H I
LO
HOLD
<Indicated value display>
<History>
Data No.
display
H I
LO
HOLD
H I
LO
HOLD
H I
LO
HOLD
H I
LO
HOLD
H I
LO
HOLD
RECALL
RECALL
RECALL
RECALL
ESC
Angle
rad
deg
Angle
rad deg
Angle
rad deg
Angle
rad deg
Angle
rad deg
Angle
rad deg
Angle
rad deg
RECALL
RECALL
Summary of Contents for TM380
Page 1: ...TM380 20MAY2021REV 1 02 TORQUE MONITOR OPERATION MANUAL ...
Page 11: ...Contents X Contents X M E M O ...
Page 147: ......