Model Two & Model Two Lite - Operation Manual
58
The Model Two displays the transmission measurement. The reference level indicates
Δ
dB to
show the difference between the current Scan Level and the Zero Reference scan. In the example
above, a 6 dB loss is seen with the transmission measurement.
The new Zero Reference remains in the Model Two’s nonvolatile memory even when the Model
Two is turned off. This enables you to measure the level’s relative change at a later time. To
perform a new Transmission Test at any time, confirm that TRANSMISSION is set to ON in the
Measurement Setup menu and then press
SPECT
. The Model Two performs a Spectrum Scan
and compares it to the reference data.
Press
UP
or
DOWN
to move the marker frequency.
You may wish to stop the scanning process so you can study the transmission graph. Simply press
F1
(HOLD). The scan marker stops moving. To resume scanning, press
F1
(TRIG).
As in Spectrum mode (absolute), other functions are available by using the
F3
key to change the
function of softkeys
F1
and
F2
.
Press
F3
to change the function of softkeys
F1
and
F2
to Scale and Ref.
Change the display scale by pressing softkey
F1
(SCALE). Change the reference level by
pressing softkey
F2
(REF) and using the
UP
and
DOWN
arrow keys to change the reference.
Note:
Channels in the Base Channel Plan that are not active on your
system have a transmission indication near 0 dB, because there was no
signal to be changed. A User Plan can be configured with only active
channels by deleting the unused channels (See
Edit User Plan
on Page
33.) This provides a transmission scan with all active data.
Note:
The Span function does
NOT
operate when the Model Two is in
the TRANSMISSION mode. For normal (absolute value) Spectrum
Measurements, set the TRANSMISSION selection to OFF.