Model Two & Model Two Lite - Operation Manual
43
Digital Channels
You can use the Model Two to measure the average power of a digital channel according to
the configured bandwidth. To do this, first set the Model Two’s channel type to DIGI (see
Edit
User Plan
on Page 33).
The level for the signal is displayed, along with a P to indicate the power level over the
specified bandwidth for DIGI mode.
To scan the channel spectrum, press
LEVEL
again.
The Marker level indicated for a DIGI signal in the channel spectrum mode is only the level at
the marker frequency and not the total power for the channel bandwidth. You can return to the
single-channel level mode (press
LEVEL
again) to read the total power of the set bandwidth.
Note:
With a Digital Channel, the Level (Live, Max,
Δ
p-p), Scale,
Reference, Auto, Marker, and
Δ
Marker may be used as described for
TV Channels.