Model Two & Model Two Lite - Operation Manual
51
Frequency Spectrum Scanning
The Model Two can be set to display spectrum measurements with spans ranging from 2.5 to 62.5
MHz. It can also be set for a full spectrum scan of the base channel plan with sampling at each
video carrier frequency.
TIP:
While in the Spectrum mode, you can use Fast Setup (Press
SET
once) to go directly to
the Measurement Setup parameters including Transmission.
For further information on Transmission operation, see
Transmission Characteristic Test
on
Page 56.
The following information is for normal (absolute) spectrum scanning.
To enter the Frequency Spectrum Scanning screen, press
SPECT
.
When the Full Spectrum scan is displayed, the Span indicator (SP) is displayed as PLAN_A-E
(full span of selected user base plan). The starting frequency (ST) is shown along with the marker
frequency and level.
Note:
TRANSMISSION mode is set up in the Measurement menu. Since
the following data is for normal (absolute) spectrum scanning,
TRANSMISSION should be set to OFF in the MEASUREMENT menu
(see
Measurement
on Page 27).
Note:
The Model Two can show spectrum data with absolute
measurements, or it can store data for comparative tests using the
TRANSMISSION feature.
Note:
With Full Spectrum scan, all video carrier frequencies in the
selected Base Channel Plan (including those disabled for Channel Scan)
are scanned.