Model Two & Model Two Lite - Operation Manual
30
Select from the following:
A checkmark appears next to each enabled limit parameter. Press
F1
(ENTER) to enable or
disable a limit parameter. Disabled limit parameters (indicated with an “X”) are not tested
during a Limit Test.
Press the
UP
and
DOWN
arrow keys
to change each limit value. You may also press
FCN,
enter numeric data, and then press
F1
to change a limit.
You may scroll to SET LIMIT DEFAULTS and press
F1
to return all limits to their standard
settings.
Once you have set the levels for each parameter, scroll to SAVE AND EXIT and press
F1
to
return to the previous screen.
MARKER
- Use this selection to switch between channel and frequency indicators for markers
in the Scan mode. Use
F1
(ENTER), or press the
UP
or
DOWN
arrow keys to change the
marker.
PRIOR MENU
- Press
F1
to return to the previous menu.
Minimum Video Level
-20 to 59 dBmV (40 to 119 dBuV)
Maximum Video Level
-19 to 60 dBmV (41 to 120 dBuV)
Maximum Video
2 to 30 dB
Minimum Video/Audio Difference
0 to 15 dB
Maximum Video/Audio Difference
5 to 30 dB
Maximum Adjacent
0 to 20 dB
24 Hour Video Deviation
0 to 20 dB
Δ
Δ