Connecting Components
Adding a secondary CPU module
37
9
Short pins 2 and 3 on jumper JP25 and set SW1 and SW2 dip switches to configure
the server to the processing speed (733 MHZ or 866 MHZ) of the CPU module. See
the table below.
System board JP25, SW1 and SW2 settings
10
Reinstall the side panel and bezel. For instructions, see
Removing and installing the
bezel and side panel
on page 31.
11
Plug in the power cable, then press the Power button to turn on the server.
12
Reinstall the operating system if necessary.
NOTE: The JP25 and SW1 should not be changed from the default settings as
shown below.
1
2
3
4
SW2 (733 MHz)
Off
Off
Off
On
SW2 (866 MHz)
Off
On
On
Off
HINT: When the server detects both CPU modules correctly, two lines of CPU
information appear on screen.
SW1
Of
f
On
1
2 3
4
JP25
3 2
1
SW2
Off
On
1 2
3 4