H9 ASD Installation and Operation Manual
177
Speed 1 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 1
.
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F540
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
F520
Setting
Speed 2 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 2
.
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F541
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
F520
Setting
Speed 3 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 3
.
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F542
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
F520
Setting
Speed 4 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 4
.
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F543
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
F520
Setting
Speed 5 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 5
.
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F544
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
F520
Setting
Speed 6 Operation Time
Program
Pattern Run
Operation Time
This parameter sets the run-time for
Preset Speed 6
.
This time is effective when used with
Group Speeds
and non-
Group Speeds
.
If the
Auto-Restart
function is activated, the search time required for the
Auto-
Restart
function will be subtracted from the
Operation Time
setting; resulting
in a shorter run time.
Direct Access Number — F545
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.1
Maximum — 6000.0
Units —
F520
Setting
F540
F545