H9 ASD Installation and Operation Manual
73
Frequency Reference Source
This selection allows the user to establish the source of the
Frequency
command.
Settings:
Use V/I
Use RR
Use RX
EOI (Keypad)
RS485
Communication Option Board
RX2 Option (AI1)
Option V/I
UP/DOWN Frequency
Pulse Input (Option)
Pulse Input (Motor CPU)
Binary/BCD Input (Option)
Display Unit
This parameter sets the unit of measurement for current and voltage values displayed on the EOI.
Wizard: Finish
This is the final screen of the
Startup Wizard
. The basic parameters of the ASD have been set. Click
Finish
to return to the
Program
mode. Additional application-specific programming may be required.
Operation
(Local)
Note:
See the section titled
EOI Features on pg. 30
for information on
Remote
operation.
To turn the motor on perform the following:
1. Connect the
CC
terminal to the
ST
terminal.
2. Press the
Mode
key until the
Frequency
Command
screen is displayed.
3. Press the
Local/Remote
key to enter the
Local
mode (green
Local
LED illuminates).
4. Turn the
Rotary Encoder
clockwise until the
desired
Frequency Command
value is
displayed in the
SET
field of the LCD screen.
5. Press the
Run
key and the motor runs at the
Frequency Command
value.
Note:
The speed of the motor may be changed while the motor is running by using the
Rotary Encoder
to change the
Frequency Command
value.
6. Press the
Stop-Reset
key to stop the motor.
Frequency Command Screen