254
H9 ASD Installation and Operation Manual
Enclosure and Conduit Plate Dimensions
The H9 ASD part numbering convention is shown below.
The enclosure dimensions for the available models (typeforms) are listed in
Tables 16
and
17
. The conduit
plates referenced are shown in
Figures 34
,
35
, and
36
.
H9
Part Numbering Convention.
Note:
The Type 1 enclosed versions of these drives meet or exceed the specification
UL 50-
1995
, the
Standard for Heating and Cooling Equipment
, and complies with the
applicable requirements for installation in a compartment handling conditioned air.
Enclosure Dimensions
Table 16. 230-Volt H9 ASD Systems.
Frame
Model Number
VT130H9U
Enclosure
Figure
Number
A
Width
(in/mm)
B
Height
(in/mm)
C
Depth
(in/mm)
Mounting Hole Dimensions
(in/mm)
Conduit
Plate
D
E
R1
R2
2
2010
Figure 31
5.2/132
11.2/285 6.1/155
8.7/220
4.5/114
0.098/2.5
0.217/5.5
Figure 34-A
2015
2025
3
2035
6.1/155
12.4/315
6.6/168
9.8/249
5.4/138
2055
4
2080
6.9/175
15.0/381
11.1/283
6.2/158
0.236/6.0
Figure 34-B
2110
5B
2160
9.1/231
19.3/490 7.6/193
15.2/386
8.3/210
0.118/3.0 0.276/7.0
Figure 34-D
2220
2270
6
2330
Figure 32
11.1/283 25.9/658 13.2/335 25.0/635
8.0/203
0.188/4.8 0.375/9.5
Figure 34-E
7B
2400
14.3/363 33.1/841 15.0/381 32.3/820
Figure 35-G
2500
2600
2750
9
210K
Figure 33
14.6/371 51.7/1313
17.6/447
50.2/1275
9.2/234
0.344/8.7
0.670/17
Figure 35-I
10
212K
15.7/399 53.1/1349
51.7/1313
9.9/252
Figure 35-J
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]