H9 ASD Installation and Operation Manual
247
*OLI
ASD Overload
Load requirement in excess of
the capability of the ASD.
• The carrier frequency is too high.
• An excessive load.
• Acceleration time is too short.
• DC damping rate is set too high.
• The motor is starting into a spinning load after a
momentary power failure.
• The ASD is improperly matched to the application.
OLM
Motor Overload
Load requirement in excess of
the capability of the motor.
• V/f parameter improperly set.
• Motor is locked.
• Continuous operation at low speed.
• The load is in excess of what the motor can deliver.
*OLR
Resistor Overload
Excessive current at the
Dynamic Braking Resistor
.
• Deceleration time is too short.
• DBR configuration improperly set.
*OP
Over-Voltage
DC bus voltage exceeds
specifications.
• ASD attempting to start into a spinning motor after a
momentary power loss.
• Incoming commercial power is above the specified
range.
• Decel time is too short.
• Voltage spikes at the 3-phase input; install inductive
filter.
• DBR required.
• DBR resistance value is too high.
• DBR function is turned off.
• Over-Voltage Stall feature is turned off.
• System is regenerating.
• Load instability.
• Disable the Ridethrough function (
F302
).
OT
Over-Torque
Torque requirement is in excess
of the setting of
F616
or
F617
for a time longer than the setting
of
F618
.
• ASD is not correctly matched to the application.
•
F616
or
F617
setting is too low.
• Obstructed load.
*POFF
Control Under-Voltage
Under-voltage condition at the 5,
15, or the 24 VDC supply.
• Defective Control board.
• Excessive load on power supply.
• Low input voltage.
PtSt
Reference Point
Two speed-reference frequency
setpoint values are too close to
each other.
• Two speed reference frequency setpoints are too close to
each other (increase the difference).
UC
Under-Current
With the
Low-Current Trip
(
F610
) parameter enabled, the
output current of the ASD is
below the level defined at
F611
and remains there for a time
longer than the setting of
F612
.
• Output current too low.
*
Reset ignored if active.
LED
Screen
LCD
Screen
Description
Possible Causes
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]