180
H9 ASD Installation and Operation Manual
Preset Speed 1 Operation Mode
Program
Pattern Run
Operation Mode
This parameter is enabled at
F560
and is used to set the speed, torque, and
direction of
Preset Speed 1
.
This screen is comprised of 4 fields that are labeled as follows:
Direction
,
Acc/
Dec Group
,
V/f Group
, and
Torque Limit Group
. Scroll to the field of
interest and press the scroll knob (Enter). Using the scroll knob, set the value
and press the scroll knob (Enter).
Parameters
F562
–
F575
are used to set the functions listed here for
Preset
Speeds
2
–
15
.
When using communications write the appropriate byte to location
F561
as
indicated below.
Settings:
0 — Forward Run
1 — Reverse Run
2 — Accel/Decel Switching 1
4 — Accel/Decel Switching 2
8 — V/f Switching Signal 1
16 — V/f Switching Signal 2
32 — Torque Limit Switching Signal 1
64 — Torque Limit Switching Signal 2
Direct Access Number — F561
Parameter Type —
Selection List
Factory Default —
Forward Run
Changeable During Run —
No
Preset Speed 2 Operation Mode
Program
Pattern Run
Operation Mode
Same as
Preset Speed 1 Operation Mode
(see
F561
).
Direct Access Number — F562
Parameter Type —
Selection List
Factory Default —
Forward Run
Changeable During Run —
No
Preset Speed 3 Operation Mode
Program
Pattern Run
Operation Mode
Same as
Preset Speed 1 Operation Mode
(see
F561
).
Direct Access Number — F563
Parameter Type —
Selection List
Factory Default —
Forward Run
Changeable During Run —
No
F/R
V/f Switch
Torque Limit
Switch 2
A/D Switch
1
2
4
8
16
32
64
0
1
1
0
1
1
0
Writing the following data to location
F561
via communications results in:
Forward Run, A/D SW 2, V/f SW 3, Torque Lim SW 4.
{
{
{
{
0=F
1=R
00=A/D 1
01=A/D 2
10=A/D 3
11=A/D 4
00=V/f 1
01=V/f 2
10=V/f 3
11=V/f 4
00=T-Lim 1
01=T-Lim 2
10=T-Lim 3
11=T-Lim 4
F561
F563