10
January 2005 © TOSHIBA TEC
e-STUDIO170F Preventive Maintenance
10 - 9
(11) Remove the process unit (toner cartridge and drum unit) from the machine by the green handle.
Place the drum unit on a level surface. Cover the unit with a clean cloth to protect the drum from
exposure to light.
Note:
Always hold the drum unit by the green handles. Do not touch the green drum area or the black
roller. Do not leave the drum unit out of the machine for an extended period. Touching the drum
or exposing the drum unit to light could lower the print quality.
Fig.10-11
(12) Wipe the paper pickup roller with a soft dry cloth. If the surfaces require moisture to remove the
dirt, use a cloth slightly dampened with water to remove the dirt, followed by a dry cloth to
remove streaks.
Fig.10-12
Process unit
Paper pickup roller