11
January 2005 © TOSHIBA TEC
e-STUDIO170F Troubleshooting
11 - 39
11.2.4
Flow chart recommended for telephone screening
Fig.11-2
Is a communication journal
printed by opening the one
touch index panel and
pressing [JOURNAL] key?
Is the AC power cord
plugged properly into an
outlet?
Is recording paper
properly loaded?
Dispatch a technician.
Dispatch a technician.
Load a document.
Dispatch a technician.
NO
NO
YES
Is the document copied
correctly by pressing the
[COPY] key and then the
[START] key?
Continued on the
next page.
Load the document
properly and press
the [COPY] key.
Is the document
properly loaded?
Plug it in properly.
Load it properly.
START
Turn the power ON with no
documents and no
recording paper loaded.
In "PAPER EMPTY"
displayed in LCD window?
Load recording paper.
YES
YES
YES
YES
YES
NO
NO
NO
NO