[ 10 ] SCANNER TEST [MENU], [9], [4], [10]
This test conducts a read/write test on all the areas of the memory contained in the DSC (IC27).
It also turns on and off the LED contained in the CIS and reads its data to check if the CIS operates nor-
mally.
1) Use the [
Ç
] or [
È
] key to select “10. SCANNER TEST”, and then press the [ENTER] key.
2) When you complete the test, press the [STOP] key to return to the standby mode screen.
3) Depending on the result of the test, replace the Main PBA or CIS by referring to
P.8-12 "[ 2 ] Main
PBA"
P.8-18 "[ 3 ] CIS".
[ 11 ] CODEC TEST [MENU], [9], [4], [11]
This test codes 10 lines of data in MH or JBIG format and decodes the data. Then it compares the
decoded result with the original data to check if the CODEC (IC16) operates normally.
1) Use the [
Ç
] or [
È
] key to select “11. CODEC TEST”, and then press the [ENTER] key.
2) When you complete the test, press the [STOP] key to return to the standby mode screen.
3) Depending on the result of the test, replace the Main PBA by referring to
P.8-12 "[ 2 ] Main PBA".
SCANNER TEST
When the test has been
completed normally
SCANNER TEST
OK
CODEC TEST
When the test has been
completed normally
CODEC TEST
OK
Summary of Contents for ESTUDIO170F
Page 2: ... 2005 TOSHIBA TEC CORPORATION All rights reserved ...
Page 192: ...e STUDIO170F Function Settings January 2005 TOSHIBA TEC 4 132 ...
Page 214: ...e STUDIO170F Mechanical Description January 2005 TOSHIBA TEC 5 22 ...
Page 308: ...e STUDIO170F Circuit Description January 2005 TOSHIBA TEC 7 78 ...
Page 372: ...e STUDIO170F Removal Replacement Adjustment January 2005 TOSHIBA TEC 8 64 ...
Page 490: ...e STUDIO170F Appendix January 2005 TOSHIBA TEC 12 8 ...
Page 491: ......
Page 492: ......