88
Command Syntax: :FUNCtion:OverCurrentFold:MANUal?
Shorthand for command: :FUNC:OCF:MANU?
Command description: This command is used to query the state of over current fold in manual mode.
Returns 1 when the over current fold function is on, and 0 when the over current
fold function is off.
Command Syntax: :FUNCtion:OverCurrentFold:PROGram
ON
or :FUNCtion:OverCurrentFold:PROGram 1
Shorthand for command: :FUNC:OCF:PROG ON or :FUNC:OCF:PROG 1
Command description: This command is used to turn on the over current fold function in the
programmable mode. Command is invalid when output is turned on
Command Syntax: :FUNCtion:OverCurrentFold:PROGram
OFF
or :FUNCtion:OverCurrentFold:PROGram 0
Shorthand for command: :FUNC:OCF:PROG OFF or :FUNC:OCF:PROG 0
Command description: This command is used to turn off the over current fold function in the
programmable mode. Command is invalid when output is turned on
Command Syntax: :FUNCtion:OverCurrentFold:PROGram?
Shorthand for command: :FUNC:OCF:PROG?
Command description: This command is used to query the state of over current fold in the programmable
mode. Returns 1 when the over current fold function is on, and 0 when the over
current fold function is off. Command is invalid when output is turned on
6.3.5.32
:FUNC:TRIG
Command Syntax: :FUNCtion:TRIG
Shorthand for command: :FUNC:TRIG
Command description: This command is used to manually trigger a surge drop. Command is invalid when
output is turned on
6.3.5.33
:FUNC:LC
Command Syntax: :FUNCtion:LoopCycle <value>
Shorthand for command: :FUNC:LC <value>
Command description: This command is used to set the total number of cycles of the memory sequence in
the programmable mode. <value> indicates the total number of cycles of the
memory sequence, ranging from 0 to 999.
Command Syntax: :FUNCtion:LoopCycle
?
Shorthand for command: :FUNC:LC
?
Command description: This command is used to query the total number of cycles of the memory
Summary of Contents for TH7105