110
1~32
0x10
0x00
0x16
0x00
0x01
0x02
0x00
0x00
or
0x01
Calculated based
on the first 8 bytes
3)
Return Instruction Format
6.4.2.22
Address 23 (Voltage Limit)
1)
Commands Description
This command is used to set the allowable difference between the output voltage and the set voltage in
manual mode. The command data range is 5.0~50.0V.
2)
Send Instruction Format
Instrument
address
Function
code
High
address
Low
address
High
bytes
Low
bytes
Number
of data
Data byte 1~4
CRC
Low
CRC
High
1~32
0x10
0x00
0x17
0x00
0x02
0x04
5.0~50.0, 4 bytes
stored in float
point type
Calculated based on
the first 11 bytes
3)
Return Instruction Format
6.4.2.23
Address 24 (Timer Seconds)
1)
Commands Description
This command is used to set the value of the timer seconds in manual mode. Instruction data byte 1
ranges from 0 to 59. The command is invalid when the output is turned on.
2)
Send Instruction Format
Instrument
address
Function
code
High
address
Low
address
High
bytes
Low
bytes
Number
of data
Data
byte 1
Data byte
2
CRC
Low
CRC
High
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x10
0x00
0x16
0x00
0x01
Calculated based on the first 6
bytes
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x10
0x00
0x17
0x00
0x02
Calculated based on the first 6
bytes