![Tonghui Electronics TH7105 Operation Manual Download Page 169](http://html1.mh-extra.com/html/tonghui-electronics/th7105/th7105_operation-manual_1126456169.webp)
164
6.4.3.65
Address 66 (Output Power)
1)
Command Description
This command is used to obtain the output power. The command is valid when the output is turned on.
2)
Send Instruction Format
3)
Return Instruction Format
Return instruction data range is 0.0~1000.
6.4.3.66
Address 67 (Output AP)
1)
Command Description
This command is used to obtain the output AP. The command is valid when the output is turned on.
2)
Send Instruction Format
3)
Return Instruction Format
When the voltage mode is “AUTO” and the voltage is less than 150V, the return instruction data range is
0.0~33.6A; when the voltage mode is “AUTO” and the voltage is greater than 150V or the voltage mode is
“HIGH”, the return command data range is 0.0~ 16.8A.
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x03
0x00
0x42
0x00
0x02
Calculated based on the first 6
bytes
Instrument
address
Function Code
Number of Data
Data Byte 1~4
CRC Low
CRC High
1~32
0x03
0x04
0.0~1000, 4 bytes
stored in float point
type
Calculated based on the first 7 bytes
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x03
0x00
0x43
0x00
0x02
Calculated based on the first 6
bytes
Instrument
address
Function Code
Number of Data
Data Byte 1~4
CRC Low
CRC High
1~32
0x03
0x04
0.0~16.8 or 0.0~33.6,
4 bytes stored in float
point type
Calculated based on the first 7 bytes
Summary of Contents for TH7105