![Tonghui Electronics TH7105 Operation Manual Download Page 111](http://html1.mh-extra.com/html/tonghui-electronics/th7105/th7105_operation-manual_1126456111.webp)
106
6.4.2.14
Address 15 (Voltage Low Limit)
1)
Commands Description
This command is used to set the voltage lower limit value in manual mode. The command data range is
0.0~300.0V. The command is invalid when the output is turned on.
2)
Send Instruction Format
Instrument
address
Function
code
High
address
Low
address
High
bytes
Low
bytes
Number
of data
Data byte 1~4
CRC
Low
CRC
High
1~32
0x10
0x00
0x0F
0x00
0x02
0x04
0.0~300.0V, 4
bytes stored in
float point type
Calculated based on
the first 11 bytes
3)
Return Instruction Format
6.4.2.15
Address 16 (Frequency High Limit)
1)
Commands Description
This command is used to set the high limit of the output frequency in manual mode. When the set voltage
is not greater than 150V, the command data range is 45.0~500Hz. When the frequency is less than 100 Hz,
the resolution is 0.1 Hz; when the frequency is not less than 100 Hz, the resolution is 1 Hz.
2)
Send Instruction Format
Instrument
address
Function
code
High
address
Low
address
High
bytes
Low
bytes
Number
of data
Data byte 1~4
CRC
Low
CRC
High
1~32
0x10
0x00
0x10
0x00
0x02
0x04
45.5~500, 4 bytes
stored in float
point type
Calculated based on
the first 11 bytes
3)
Return Instruction Format
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x10
0x00
0x0F
0x00
0x02
Calculated based on the first 6
bytes
Instrument
address
Function
Code
High Address
Low Address
High bytes
Low bytes
CRC Low
CRC High
1~32
0x10
0x00
0x10
0x00
0x02
Calculated based on the first 6
bytes