3.
Communication parameters
5-8
5. Operation and
Adjustment
TNU
3-2
Net device list
Type
Not connected
TSC
TLC
THC
Any
Set the driver controller to be connected to TNU.
This is set to "Any" upon shipping and communicates with all the 16 shafts. By setting a driver
controller connected to each ID, communication with shafts that are not connected can be omit-
ted to improve the communication performance.
Setting is performed using the setup tool D-STEP
(-> P.6-6).
Setting values can be selected from
the following items.
When not concerned with the type of driver controller connected, or when connecting to new
models in the future, "Any" can be selected.
Input Mode
IO
Simple
Half
Full
◦
Input Mode
Sets the input mode for the driver controller connected to each ID.
It is set to "IO" before shipment and input mode can be set for each ID.