3. Wiring
1.
How to wire
3-6
TNU
Wiring example of each driver controller
・
Connecting TDO will open the internal relay K1, and the TDO emergency stop switch is acti-
vated.
・
While TDO is not connected, the internal relay K1 is closed.
・
When TDO or the emergency stop of the CN4 (1) and (2) pins is input to TNU, the emergen-
cy stop is entered in all the driver controllers connected to the TJU.
・
To enter the emergency stop individually to each driver controller, install an emergency stop
circuit to each driver controller.
• Do not connect the driver controller TSC and TLC to the CN5 (1) pin (S1).
Doing so may disable the emergency stop and cause damage or fault.
• Be sure to set the DC of TNU, TSC, TLC, and THC to 0 V respectively.
Otherwise, the communication may not be established.
• To enter the emergency stop to THC, install an external relay and disconnect the CN5 (3) and (4)pins of the THC.
Important