6. Setup tool D-STEP
3.
Operation method
6-10
TNU
3-4
Alarm history display screen
(1) Reset alarm
: Reset the generated alarm.
(2) History clear
: Deletes the alarm history from TNU memory.
(3) Update
: Loads the alarm history from TNU memory to D-STEP.
For alarm contents, see the alarm list
(-> P.8-2)
.
The alarm history saves 50 past alarms and power ON information.
3-5
Setting before communication with driver controller (Important)
• From D-STEP, be sure to set the parameter No.48 TDO enable function to "Invalid" before performing the
program edit and operation command of each driver controller.
If it keeps "Valid", communication cannot be established. In addition, return back to "Valid" to do it from TDO.
Important
(3)
(2)
(1)