2.
CC-Link communication specifications
4-27
4. TNU functions
TNU
2-4
Number of occupied stations / multiple settings (CC-Link Ver.2.00 only)
2-5
CSP and CSP+ files (TNU Firmware Ver.1.2 or later)
With CC-Link Ver.2.00, the number of occupied stations and multiple settings can be selected.
Net device list settings are possible within a range not exceeding the link point count capacity for
number of stations and multiple settings.
The RWw / RWr link point (word) count for each number of occupied stations / multiple settings and
that required for each mode are as follows.
List of RWw / RWr link point counts for each number of occupied stations / multiple settings
Multiple settings
Number of occupied stations
1 time
2 time
4 time
8 time
1 stations
32
2 stations
32
64
3 stations
24
48
4 stations
16
32
64
List of RWw / RWr link point counts for each input mode
IO
Simple DVC
Half DVC
Full DVC
Required link point count
1
3
8
14
CSP and CSP+ files contain information on TNU specifications and device allocation, etc.
(You can download this free program from the electrical actuator site: https://tech.thk.com/)
www.thk.ru