3. Wiring
1.
How to wire
3-9
TNU
1-4
Connect TJU
1-4-1
Connection between TNU and TJU or TJU and TJU
Prepare a cable by yourself.
The cables between TJU and TNU and between TJUs should be Ethernet ones of CAT5e and
above. The following industrial Ethernet cables are recommended:
Manufacturer
Model
Length
Nihon Electric Wire & Cable Co., Ltd.
IETP-SB001M
1m
IETP-SB005M
5m
IETP-SB010M
10m
National Instruments Corporation
151733-02
2m
151733-05
5m
151733-10
10m
Please prepare the cable whose length according to the system (maximum length of trunk cable
20 m: See the following figure).
Connection between TNU and TJU: Connect the TNU's CN3 to the TJU's LINE IN.
TJU-TJU connection: Connect the TJU's LINE OUT and TJU's LINE IN.
*
CN3
LINE IN
LINE IN
LINE IN
LINE OUT
LINE OUT
*
Length of trunk cable = a + b + c
• Use an Ethernet straight cable.
Using a cross cable may cause damage or fault.
Important
• At the end of TJU, turn the termination resistance ON (TERM.ON) (
*
mark in the figure above).
Important