![THK TJU Instruction Manual Download Page 35](http://html1.mh-extra.com/html/thk/tju/tju_instruction-manual_1107536035.webp)
3. Wiring
1.
How to wire
3-7
TNU
1-3
Connect to master devices
1-3-1
Connect to master devices
1. Connect a CN1 connector-compliant cable according to the network type.
Pin number Terminal name
1
DA
2
DB
3
DG
4
SLD
5
-
TNU_front_背景なし.tif
2013年11月21日
C:\Documents and Settings\08552\デスクトップ\TNU_front_背景なし.tif
19:00:27
TNU-CC
TNU-EC
TNU-EP
* Please prepare the cable
by yourself.
The cable connected must
be the shielded cable of
CAT5e or higher.
The following industrial
Ethernet cables are
recommended.
EtherCAT: XS6 Series
(OMRON Corporation)
EtherNet/IP: XS5 Series
(OMRON Corporation)
TNU-CC wiring diagram
DA
DB
DG
SLD
DA
DB
DG
SLD
DA
DB
DG
SLD
Termination
resistance
Termination
resistance
Master station
Slave station
Slave station
CC-Link
dedicated cable
(Blue)
(White)
(Yellow)
(Blue)
(White)
(Yellow)
(Blue)
(White)
(Yellow)
(Blue)
(White)
TNU-DV connection example
Trunk/branch cables: DeviceNet dedicated cables
Termination resistance
Communication
power supply
Trunk cable
Trunk cable
Trunk cable
Power tap
T-branch tap
T-branch tap
Branch cable
Slave
Slave
Master
Slave
Branch cable
Trunk cable
Trunk cable
Pin number Terminal name
1
V-
2
L
3
SLD
4
H
5
V+
TNU-DV
Termination resistance
www.thk.ru
тел. +7(499) 703-39-86