Filter Registers Reference
180
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Filter
4.11.21 Filter YN Clamp High Register (FILTERYNCLPHI)
Address 00060050 – Filter 2 YN Clamp High Register
Address 00090050 – Filter 1 YN Clamp High Register
Address 000C0050 – Filter 0 YN Clamp High Register
Figure 4-26. Filter YN Clamp High Register (FILTERYNCLPHI)
23
0
YN_CLAMP_HIGH
R/W-0111 1111 1111 1111 1111 1111
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 4-21. Filter YN Clamp High Register (FILTERYNCLPHI) Register Field Descriptions
Bit
Field
Type
Reset
Description
23-0
YN_CLAMP_HIGH R/W
0111
1111
1111
1111
1111
1111
Sets the upper limit of YN value. If calculated YN exceeds this threshold, the YN
register will be set to YN_CLAMP_HIGH