Fault Interrupt Pending Register (FAULTINTPEND)
290
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
GIO Module
7.6
Fault Interrupt Pending Register (FAULTINTPEND)
Address FFF7FA1C
Figure 7-6. Fault Interrupt Pending Register (FAULTINTPEND)
6
5
4
3
2
1
0
TMS_INT_PEND
TDI_INT_PEND
TDO_INT_PEND
FLT3_INT_PEND
FLT2_INT_PEND
FLT1_INT_PEND
FLT0_INT_PEND
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 7-6. Fault Interrupt Pending Register (FAULTINTPEND) Register Field Descriptions
Bit
Field
Type
Reset
Description
6
TMS_INT_PEND
R/W
0
TMS has caused an interrupt. Writing a 1 to a bit will clear the interrupt flag
0 = No Interrupt detected (Default)
1 = Interrupt pending
5
TDI_INT_PEND
R/W
0
TDI has caused an interrupt. Writing a 1 to a bit will clear the interrupt flag
0 = No Interrupt detected (Default)
1 = Interrupt pending
4
TDO_INT_PEND
R/W
0
TDO has caused an interrupt. Writing a 1 to a bit will clear the interrupt flag
0 = No Interrupt detected (Default)
1 = Interrupt pending
3
FLT3_INT_PEND
R/W
0
FAULT[3] has caused an interrupt. Writing a 1 to a bit will clear the interrupt flag
0 = No Interrupt detected (Default)
1 = Interrupt pending
2
FLT2_INT_PEND
R/W
0
FAULT[2] has caused an interrupt. Writing a 1 to a bit will clear the interrupt flag
0 = No Interrupt detected (Default)
1 = Interrupt pending
1
FLT1_INT_PEND
R/W
0
FAULT[1] has caused an interrupt. Writing a 1 to a bit will clear the interrupt flag
0 = No Interrupt detected (Default)
1 = Interrupt pending
0
FLT0_INT_PEND
R/W
0
FAULT[0] has caused an interrupt. Writing a 1 to a bit will clear the interrupt flag
0 = No Interrupt detected (Default)
1 = Interrupt pending