Memory Controller – MMC Registers Reference
472
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Memory
15.1.4 Peripheral Location Register (PLOC)
Address FFFFFD34
Figure 15-4. Peripheral Location Register (PLOC)
15
0
LOC
R/W-0000 0000 0000 0000
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 15-8. Peripheral Location Register (PLOC) Register Field Descriptions
Bit
Field
Type
Reset
Description
15-0
LOC
R/W
0000
0000
0000
0000
These 16 bits represent the peripheral location bits, which correspond to each of the
16 peripheral selects.
0 = Peripheral is internal (Default)
1 = Peripheral is external