Registers
349
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Advanced Power Management Control Functions
9.12.4 Global I/O Value Register (GLBIOVAL)
Address FFF7F024
Figure 9-14. Global I/O Value Register (GLBIOVAL)
29
0
GLOBAL_IO_VALUE
R/W-00 0000 0000 0000 0000 0000 0000 0000
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 9-19. Global I/O Value Register (GLBIOVAL) Register Field Descriptions
Bit
Field
Type
Reset
Description
29-0
GLOBAL_IO_
VALUE
R/W
00 0000
0000
0000
0000
0000
0000
0000
This register set the output value of the digital I/O pins when configured as outputs
0 = Digital I/O pin configured as low in output mode (Default)
1 = Digital I/O pin configured as high in output mode
Bit assignment is done by this table:
BIT
PIN_NAME
BIT
PIN_NAME
29
FAULT[3]
14
CONTROL
28
ADC_EXT_TRIG
13
ALERT
27
TCK
12
EXT_INT
26
TDO
11
FAULT[2]
25
TMS
10
FAULT[1]
24
TDI
9
FAULT[0]
23
SCI_TX[1]
8
SYNC
22
SCI_TX[0]
7
DPWM3B
21
SCI_RX[1]
6
DPWM3A
20
SCI_RX[0]
5
DPWM2B
19
TMR_CAP
4
DPWM2A
18
TMR_PWM[1]
3
DPWM1B
17
TMR_PWM[0]
2
DPWM1A
16
PMBUS-CLK
1
DPWM0B
15
PMBUS-DATA
0
DPWM0A